POLON 4900 - Ugunsdzesības signalizācijas vadības panelis

2,027.00
(Ieskaitot nodokli)
POLON 4900
1 prece(s)
+

Fire alarm control panel POLON 4900

Type:
Addressable control panel
Purpose:        
Fire alarm control panel POLON 4900 is designed to integrate all interactive, addressable POLON 4000 fire alarm system elements. The control panel coordinates operations of all units in the system. The control panel makes decision about actuation of fire alarm, control of cooperated signaling and fire protection equipment and giving of information to monitoring center or supervising system.
The POLON 4900 control panel is recommended for protection of various buildings (especially huge buildings) such as hotels, office buildings, banks, warehouses, monumental or "intelligent" buildings etc. The control panel can operate in a network with other POLON 4900 and POLON 4500 control panels.

Co-operating elements:        
a/ addressable fire detector range 4046:
• universal optical smoke detector DUR,
• optical smoke detector DOR,
• ionizing smoke detector DIO,
• heat detector TUN,
• multisensor smoke and heat detector DOT,
• multisensor smoke and flame detector DPR,
• wireless, universal optical smoke detector DUR-4047,
b/ conventional detector range 40 (installed on ADC-4001M side line):
• heat and flame detector TOP,
• flame detector (UV) PUO,
• intrinsically safe detectors,
• beam smoke detector DOP
c/ manual call points:
• for indoor use ROP-4001M,
• for outdoor use ROP-4001MH
d/ input, output devices:
• input-output device EKS-4001
• multioutput control device EWS-4001,
• multiinput supervising device EWK-4001
e/ adapters:
• addressable device ADC-4001M,
• addressable device ACR-4001 for wireless detectors
f/ addressable signaling device SAL-4001
g/ parallel indicating terminal TSR-4000
h/ universal control panel UCS-4000

Certificate:               
CNBOP 2169/2006
Technical data:
- main power supply                             230V
- reserve power supply                         battery 2x12V (17 - 90Ah)
- current consumption by the
line elements from the detector line        max. 50mA
- number of detector lines                     4 (8 with additional MSL-2M module)
- max number of addressable
elements in the line                               127
- number of detection zones                 1024
- number of  alarm variants                   17
- non-potential relay outputs                 16 (load current 1A 30V)
- potential outputs                                8
- supervising lines                                 8
- operation temperature                       -5ºC ÷ +40ºC