New ver. 4.00 available.
Starting from firmware ver. 4.00, the CB32 control panel features newly added options, including:
• Panel control by SMS from up to 16 phone numbers (arming/disarming, blocking zones, requesting system status);
• Panel arming and disarming by CLIP from 16 phone numbers;
• Alarm system notification by CLIP and SMS to up to 8 mobile phone numbers;
• Panel faults notification by SMS;
• Mobile network signal strength monitor;
• Mobile phone communication test with CB32 panel by CLIP or SMS at specified time or intervals;
• New operation modes with two-channel remote transmitter and operation with four-channel remote;
• Easy control panel clock adjustment.
This extremely small and compact wireless control panel is designed for use in security systems, burglary and emergency alarms, and access control in houses, offices, and other premises. The panel can be operated by up to 16 users and controls up to 32 wireless Elmes detectors. Additionally, its two perimeter wired inputs allow connection of any two wired detectors. Selected standard features and options include: two modes of partial arming; monitoring and alarming with the use of mobile GSM phones; keypad and hand transmitter arming and disarming; registering of the last 256 events timed by internal real time clock. Two internal backup rechargeable batteries allow autonomous operation in case of mains supply failure. Fitted hardware features include an internal acoustic siren, three user-defined universal programmable outputs intended for connection of external signaling and alarming devices, clear lit LCD readout display, on-board power supply for connected external mobile phone, and a full-size keypad for easy programming and daily arming/disarming operation.
To connect a GSM phone with the CB32 control panel, a dedicated interface cable is required and may be optionally ordered from the seller.
CB32 firmware < 4.00 | CB32 firmware >= 4.00 | ||
Siemens | C60, C65, CX65 | C65 | interface KB2-C60 |
Sony-Ericsson | T68, T230, T630, K300i, K700, K700i | T68, K300i, K700i, K508i | interface KB2-T68 |
Interface KB2-C60 and KB2-T68 diagram >>>
Sony Ericsson is a registered trademark of Sony Ericsson Communications AB.
Siemens is a registered trademark of Siemens AG.
PC Software and CB32 firmware available for download:
INSTALL | PC software for CB32 configuration. |
USB drivers | Drivers for USB-R interface cable. |
CB32 control panel firmware | |
*Please read \"readme\" file before installation. |
SPECIFICATION
Feature Name | Value |
Wireless Detectors Supported | Up to 32 |
Wired Detectors Supported | 2 parametric alarm zones |
Users Supported | 16 (4 with administrator rights) |
GSM Phone Interface | Monitoring of alarms with SMS/CLIP notification |
Backup Power Supply | Two AA rechargeable batteries up to 2700mAh each |
Battery Operation Time | Up to 72 hours (with 2700mAh batteries) |
Event Memory | Non-volatile EEPROM memory for last 256 events |
Programmable Outputs | OUT 1-3, polymer fuse protected, up to 1A current draw |
Detector Presence Monitoring | Yes, by control panel |
Arming/Disarming | Via keypad password or remote control transmitter |
Partial Arming Modes | Yes |
Panic/Robbery Alarm | Activated by remote control |
Acoustic Signaling | Beeps for entry in \"chime type\" zone |
Internal Siren | 92dB (at 40cm distance) |
Receiver Type | Superheterodyne 433.92 MHz, sensitivity better than -104dBm |
Power Supply | 12VDC/300mA AC power pack included |
Operating Temperature | Indoor use only, 0°C to +40°C |
External Dimensions (without antenna) | 110/122/32mm (width/height/thickness) |
Available backlight color versions:
CB32N – blue,
CB32Z – green.
For more details, see the CB32Z Catalogue Card and CB32N Catalogue Card. Manual (PDF)