POLON 4100 - Fire alarm control panel

886.00
(sis. alv 21%)
POLON 4100
99 tuote(tta)
+

Fire alarm control panel POLON 4100

Type:
Addressable control panel
Purpose:        
Fire alarm control panel POLON 4100 is designed to integration of all interactive, addressable POLON 4000 fire alarm system elements. The control panel co-ordinates of operation of all units in the system. The control panel makes decision about actuation of fire alarm, control of co-operated signaling and fire protection equipment and giving of information to monitoring center or supervising system.
The POLON 4100 control panel is recommended for protection of various buildings (especially a medium size buildings) such as hotels, office buildings, banks, warehouses, monumental or "intelligent" buildings etc.
Co-operating elements:        
a/ addressable fire detector range 4043 and 4046:
• universal optical smoke detector DUR,
• optical smoke detector DOR,
• ionizing smoke detector DIO,
• heat detector TUN,
• multisensor smoke and heat detector DOT,
• multisensor smoke and flame detector DPR,
• wireless, universal optical smoke detector DUR-4047,
b/ conventional detector range 40 (installed on ADC-4001M side line):
• heat and flame detector TOP,
• flame detector (UV) PUO,
• intrinsically safe detectors,
• beam smoke detector DOP
c/ manual call points:
• for indoor use ROP-4001M,
• for outdoor use ROP-4001MH
d/ input, output devices:
• input-output device EKS-4001
• multioutput control device EWS-4001,
• multiinput supervising device EWK-4001
e/ adapters:
• addressable device ADC-4001M,
• addressable device ACR-4001 for wireless detectors
f/ addressable signaling device SAL-4001
g/ parallel indicating terminal TSR-4000

Certificate:               
CNBOP 2276/2006
Technical data:
- main power supply                            230V
- reserve power supply                        battery 2x12V (17 - 38Ah)
- current consumption by the
line elements from the detector line       max. 50mA
- number of detector lines                    2
- max number of addressable
elements in the line                               64
- number of detection zones                 265
- number of  alarm variants                  17
- non-potential relay outputs                 8 (load current 1A 30V)
- potential outputs                                2
- supervising lines                                 2
- operation temperature                       -5ºC ÷ +40ºC